HIVE 13 // MONITORING // HV-ENG-0013
ALL SYSTEMS NOMINAL ·
MONITORING & ANALYTICS · DOC CLASS — ENGINEERING

Alarm Escalation - Raising and Routing NectarNet Alarms

Every stream on the NectarNet Mesh is scored against a threshold band by MELISSA. When a band is breached, MELISSA raises an alarm, classifies it into one of four severity tiers, deduplicates it against open incidents, and escalates it to the responders that tier demands. This page documents that pipeline: the severity matrix, the detection-triage-response flow, the per-channel thresholds, and the Black-tier auto-page that pulls in the Director and the response drill.

The NectarNet control floor and live alarm board
Doc Control HV-ENG-0013 Revision Rev A Effective 2091-01-01 Owner Engineering · NectarNet Curated by MELISSA Classification INTERNAL // QUANTUM-ZONE-TASK-FORCE EYES-ONLY

How MELISSA Raises an Alarm

MELISSA watches NectarNet telemetry continuously, comparing each metric to its calibrated band. A breach opens a candidate alarm; MELISSA enriches it with neighbouring streams, assigns a severity, and either folds it into an existing incident or escalates it. Lower tiers stay on the analytics queue; higher tiers reach people, and the top tier reaches the response & drill ladder automatically. The matrix below defines what each tier means and who it reaches.

Alarm-Severity Matrix

Four tiers, colour-coded from Green to Black. Severity is set by the worst breach contributing to the alarm; an alarm only escalates downward (toward Black), never silently upward.

SeverityExample triggerNotifiedResponse targetEscalation
GREEN All metrics within band; mesh coverage nominal. Logged only — visible on the Live Command Wall. None; held as baseline.
AMBER Single relay offline; brief floral-load dip; minor colony-weight drift. NectarNet engineering queue (MELISSA digest). Next shift Auto-promotes to Red if the breach persists past one shift.
RED Brood temp out of band; queen-piping signature; sustained weight loss; coverage gap. On-call apiary tech + duty analyst at the duty desk. ≤ 30 min Opens a response drill if unacknowledged in 30 min.
BLACK HCL-4 containment breach; Cryo Vault power loss; neonic spike; multi-node partition. Director, duty officer, and the full drill ladder. Immediate Auto-pages the Director and triggers the drill — see below.

Detection · Triage · Response

Every alarm moves through the same three stages before it reaches a human.

📡Detection

MELISSA on NectarNet

MELISSA scores each NectarNet stream against its band in real time. A sustained or sharp breach opens a candidate alarm, stamped with the source channel, node, and the telemetry that tripped it. Raw signal keeps flowing to the Live Command Wall even if scoring is degraded.

Triage

Auto-classify & dedupe

MELISSA assigns a severity tier from the matrix, then deduplicates: a new alarm that matches an open incident's channel and signature is folded in rather than re-raised, so a single event never floods the desk. Correlated breaches across nodes are merged into one ranked incident.

🜂Response

Route to duty desk / drill

The classified incident is routed to the responders its tier demands — engineering queue, duty desk, or the drill ladder. Acknowledgements, holds, and clears are tracked back on the status board until resolved.

Example Channels & Alarm Thresholds

A sample of the NectarNet channels MELISSA scores, with the band that raises each tier. Every channel maps to a named figure in the Metrics catalogue; thresholds below are the 2091 baseline calibration.

ChannelAmberRedBlackLinked metric
Brood temperature ±0.5 °C drift from 35 °C Outside 33–36 °C for > 10 min Outside 30–38 °C — brood loss imminent Brood Temperature
Neonic residue 1–4 ppb in entrance air 4–10 ppb confirmed in nectar/pollen > 10 ppb — acute exposure event Pesticide Telemetry
Mesh coverage Corridor coverage 95–98% Coverage 85–95% or cell gap < 85% or multi-node fabric partition Corridor Coverage
Swarm readiness Pre-swarm hum + weight plateau Queen piping + capped swarm cells Active swarm departure detected Acoustic Signature
Containment integrity HCL seal pressure drift HCL-3 seal degraded; airlock fault HCL-4 breach or Cryo Vault power loss Containment Integrity
Black-tier auto-pages the Director and triggers the drill. A confirmed Black event — an HCL-4 containment breach or a Cryo Vault power loss — does not wait for a human to escalate it. MELISSA pages the Director directly, holds the alarm at Black until acknowledged on-scene, and automatically opens the response drill. Nothing about a Black alarm is auto-cleared.
Where alarms live. See the NectarNet Mesh for the sensing layer that feeds these alarms, the status board for the current incident roll-up, the Live Command Wall for live streams, and the MELISSA Console for the analytics that raise and rank them.

← Back to NectarNet Mesh